This
transition is an exclusive development from Marlin Manufacturing
Corporation. After the wire extension has been spliced
to the sheathed wire, the transition is molded with a thermoset
compound. This transition exhibits the characteristics of high
strength and resistivity and protects the splice against moisture,
vibration and mechanical damage and also incorporates a strain
relief for the wires that obsoletes springs and adapters. Standard
transitions can be used in ambient temperatures to 400°F (205°C).
High temperature transitions are available for use in ambient
temperature to 800°F (425°C).
TRANSITION
DIMENSIONS
| Sheath
Size Diameter (Inches) |
Transition*
Size Diameter (Inches) |
Transition
Length "L" (Inches) |
Stranded
Wire Extension Gauge B & S |
| 0.187 |
0.312 |
1.000 |
24 |
| 0.250 |
0.437 |
1.000 |
24 |
| 0.375 |
0.625 |
1.000 |
24 |
*Same
diameter transitions are available in o.187" diameter and larger
sheath sizes.

EXTENSION
TYPES
| Marlin
Code |
Extension
Types |
| XXX |
NONE |
| MTO |
TEFLON
INSULATED
260°C (500°F) |
| MGO |
FIBERGLASS
INSULATED
482°C (900°F) |
NOTES:
- For SS
Flex Armor Cable over Extension, add "#" to code: e.g. "MT3"
- For SS
Overbraid over Extension, add "1" to code e.g. "MT1"
TRANSITIONS
- Extensions
include transitions for use to 205°C (400°F)
- For Hi-Temp
transition 425°C (800°F) use "H" to code e.g. "HTO"
- For transition
"same size" as Sheath O.D. use "E" to code e.g. "ETO"
- For "Probe
Handle" transition use code "P" e.g. "PTO" (good for 350°F -
not available in hi-temp).

Teflon-Teflon:
Teflon insulates individual conductors followed by an overall
teflon jacket. Superior abrasion and moisture resistance. Resists
most acids and vapors. Recommended operating temperature -90°F
to 500°F.
Glass-Glass:
Glass yarn is applied over each conductor then impregnated with
silicone varnish plus both conductors are covered with a braid
of glass yarn also with silicone varnish. Fair resistance to abrasion
and moisture. Recommended operating temperature to 900°F. Varnish
is destroyed above 400°F.
Glass-Glass
with Stainless Steel Overbraid: Same as Glass-Glass with added
abrasion resistance.
Stainless
Steel Armor Tubing: Can be used over any wire extension for
added mechanical damage and abrasion resistance.

For
more information regarding Platinum Resistance Thermometers,
Please consult your Marlin catalog, Pages C-3 to C-19.
If
you do not have a Marlin Catalog - Click
Here!