SR 1000 Specifications Continued

 

Recording
Construction/Power Source

Alarm:
At the right side of the chart, Ch.No., type of alarm, ON/OFF time (h/m) will be printed.

Dimensions: (approx.)
144(W) x 144(H) x 220(D) mm
Weight: (approx.)
1-pen, 3.1kg(6.8lbs); 2-pen, 3.3kg(7.3lbs); 3-pen, 3.5kg(7.7lbs); 6-dot, 3.4kg(7.5 lbs)
Periodic Printout: At the left side of the chart, date (m/d), time (h/m), chart speed, and measured data of every channel will be printed.
1. Channel No.
2. Measuring Printout
3. Scale Printout (At 0% and 100% values will be printed.)
4. Printout of recording colors (pen model only).
5. Date, time and chart speed
Case: Drawn Steel
Front Door: Aluminum Die Casting
Color: Black (Mansell 0.8 Y 2.5/0.4)
Panel Thickness:
2 to 26 mm
(0.78 to 1.02 inch)
Message Printout: 5 message, 16 characters
 
Chart Speed Change Printout:
Printouts of the chart speed and time when the change occurs can be made by the user.
Power Source:
Rated Power Voltage: 100 to 240 V-AC
Usable Power Voltage Ranges: 90 to 132, 180 to 250 V-AC
Rated Power Frequency: 50/60 Hz


100 V-AC
240 V-AC
Max.
3 pen
26 VA *
36 VA *
70 VA
6 dot
25 VA *
30 VA *
50 VA
(*) for stable input
List Printout :
Prints listing of range settings, alarm settings, and other parameters.
Manual Printout :
Provides a digital printout of measurement results.
General Specifications
SET UP List Printout:
Prints listing of setting SET up mode.
Ambient Temperature and Humidity:
0 to 50°C, 20 to 80% R.H. (at 5 to 40°C)
Display
Mounting:
Up to 30° backward from vertical
Display System:
LED (7 segments, 7 character positions)
Display & Status Indicator Items
Measured data (channel no., alarm type, measured value), date, time, OFF (No display)
Insulation Resistance:
Between terminals and ground: 20 M-Ohms or more (at 500 V-DC)
Clock:
With calendar function
Computing Functions
Clock Accuracy:
100 ppm, however not including error due to turning ON/OFF POWER
Linear Scaling :
Scaling Ranges: DC V
Scaling Limits: -19.999 to 20.000
Data Display/Printout Range: -19.999 to 20.000
Decimal Point Position: User-Set
Engineering Units: User-Set
(6 characters MAX)
Dielectric Strength:
Power terminals to ground:
Contact output terminals to ground:
1,500 V-AC (50/60 Hz) for one minute
Measuring input terminals to ground:
1,000 V-AC (50/60 Hz) for one minute
Input terminals to input terminals (between measuring channels):
1,000 V-AC (50/60 Hz) for one minute
(Except dot-printing model's RTD - 'b' terminals are interconnected.)
Interchannel Difference (Delta T):
Between any two channels (Reference CH < Measurement CH)
Range: DCV, TC, RTD
Memory Backup:
Lithium battery to preserve setup parameters.
Life: approx. 10 years (at 23°C +/-2°C, 55 +/-10% RH, for standard model).
Battery end-of-life displays: 'BAT' status on display.
Square Root:
Available for DCV range.
Scaling Limits: -19.999 to 20.000
Data Display/Printout Range: -19.999 to 20.000
Decimal Point Position: User-Set
Engineering Units: User-Set
Panel Key-lock:
Can be set for RCD, PRINT, FEED key
Setting Data Protection:
Requires a password
Offset Function:
Range Types: DCV, TC, RTD, SCL
Compensation: 10% of recording span
sr1000
Alarms
Number of Alarm Levels:
Four levels/channel
Types:
High, Low, delta high, and delta low
Alarm Indications:
Shared alarm indicator on.
Alarm Recording:
Prints channel number, alarm type, and time ON or OFF on right side of chart.
Alarm Relay Contact Output (optional function):
2, 4, or 6 points; OR output.
Energize or de-energize on alarm selectable (shared by all relays).

For more information regarding Marlin Instruments,
Please call us at 1-800-321-6648 or email us at marlincle@marlinmfg.com

 

 
Go to top of page

Marlin Manufacturing Corporation · 12800 Corporate Drive · Parma · Ohio · 44130

Phone: (216) 676-1340 or (800) 321-6648·
Fax: (216) 676-1344 · Email: marlincle@marlinmfg.com
Company Profile Contact Us Home Home

Copyright 2003 Marlin Mfg. Corporation. All Rights Reserved.

Site Design: tlhalfacre@ameritech.net & Abstract Productions