*Same
diameter transitions are available in 0.125" diameter and larger
Marlox.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Marlin
Code
|
Extension Types |
|---|---|
|
XXX
|
NONE
|
|
MTO
|
TEFLON
INSULATED
260°C (500°F) |
|
MGO
|
FIBERGLASS
INSULATED
482°C (900°F) |
TRANSITIONS
Teflon-Teflon: Teflon insulates individual conductors followed by an overall teflon jacket. Superior abrasion and moisture resistance. Resists most acids and vapors. Recommended operating temperature -90°F to 500°F.
Glass-Glass: Glass yarn is applied over each conductor then impregnated with silicone varnish plus both conductors are covered with a braid of glass yarn also with silicone varnish. Fair resistance to abrasion and moisture. Recommended operating temperature to 900°F. Varnish is destroyed above 400°F.
Glass-Glass with Stainless Steel Overbraid: Same as Glass-Glass with added abrasion resistance.
Stainless Steel Armor Tubing: Can be used over any wire extension for added mechanical damage and abrasion resistance.
Copyright 2003 Marlin Mfg. Corporation. All Rights Reserved.