Thermocouple Wire
General Information - Resistance

 

NOMINAL THERMOCOUPLE RESISTANCE Ohms per Double Foot @ 68°F (20°C)
Wire (GA)
B & S
Wire Size
DIA.
ANSI/ASTM TYPES
J
K
T
E
S
R
B
6
0.162
0.014
0.023
0.012
0.027
0.007
0.007
0.008
*7
0.144
0.021
-
-
-
-
-
-
8
0.128
0.022
0.036
0.019
0.044
0.010
0.010
0.013
14
0.064
0.089
0.147
0.074
0.176
0.044
0.044
0.054
16
0.050
0.141
0.232
0.117
0.277
0.069
0.069
0.086
18
0.040
0.229
0.377
0.190
0.450
0.112
0.113
0.139
20
0.032
0.357
0.588
0.297
0.702
0.175
0.178
0.218
24
0.020
0.905
1.488
0.745
1.778
0.449
0.453
0.550
26
0.015
1.441
2.45
1.20
2.84
0.701
0.708
0.875
28
0.012
2.297
3.59
1.92
4.33
1.062
1.073
1.392
30
0.010
3.65
6.02
2.94
7.19
1.794
1.813
2.213
36
0.005
14.66
24.08
12.22
28.80
7.150
7.226
8.897
(*) Double feet 7 GA Type J = 7 Ga Iron/8 Ga Constantan

 

For more information regarding Marlin Thermocouple Wire,
Please call us at 1-800-321-6648 or email us at marlincle@marlinmfg.com

 

 

 
Go to top of page

Marlin Manufacturing Corporation · 12800 Corporate Drive · Parma · Ohio · 44130

Phone: (216) 676-1340 or (800) 321-6648·
Fax: (216) 676-1344 · Email: marlincle@marlinmfg.com
Company Profile Contact Us Home Home

Copyright 2003 Marlin Mfg. Corporation. All Rights Reserved.

Site Design: tlhalfacre@ameritech.net & Abstract Productions